محصولات

فرودگاهی | پل انتقال مسافر

پل انتقال مسافر

TMB Bridge 3T

"3-Tunnel" Glass & Steel Wall Passenger Boarding Bridge

APPLICATION
Apron Docking & Boarding
COMPLIANCE with
International Civil Aviation Organization (ICAO) and in particular Annex 14
Federal Aviation Administration (FAA) AC No. 150/5220-21C
American Society of Testing Materials (ASTM)
International Electric Committee (IEC)
US National Electrical Manufactures Association (NEMA)
US National Fire Protection Association (NFPA417)
American Welding Society (AWS)
Steel Structures Painting Council (SSPC)
Society of Automotive Engineers (SAE)


TMBBridge "3-Tunnel" General Information
TYPE Fully Extended Fully Retracted Travel Max OP Limit Max OP Limit
3T- 20/11 20.0m 11.5m 8.5m 18.4m 12.4m
3T-23/13 23.5m 13.0m 10.5m 21.9m 13.9m
3T-27/14 27.0m 14.5m 12.5m 25.4m 15.4m
3T-30/16 30.5m 16.0m 14.5m 28.9m 16.9m
3T-34/17 34.0m 17.5m 16.5m 32.4m 18.4m
3T-37/19 37.5m 19.0m 18.5m 35.9m 19.9m
3T-41/20 41.0m 20.5m 20.5m 39.4m 21.4m
3T-44/22 44.5m 22.5m 22.5m 42.9m 22.9m

 

DESIGN PARAMETRS
Dimensional Charasteristics: (Minimum Dimesions)
Tunnels (Minimum "A" tunnel only) Floor = Width = 1.5m , Interior = Height = 2.1m , Inerior Cab = Width = 3.5m
Rotunda Interface Width = 1.5m , Height = 2.2m

 

OPERATIONAL CHARACTERISTICS
Rotunda Swing 175°(87.5°cw/87.5°ccw of centerline)
Cab rotation 122.5°(90°ccw/32.5cw)
Cab roation speed 3°/sec.
Vertical rate of travel/lift Automatic = 0.9m/min , Manual = 1.5m/min
Horizontal rate of travel 0~0.4m/s

 

Environmental Charastristics
Bridge operations at tempretures from -20°C to 50°C

 

Power Requirements
380 VAC , 3 Phase , 50 Hz